Platform detection at urban rail transit stations

Material Analysis 百检检测 2024-01-08

This standard specifies the general lighting regulations、 lighting illuminance values、 lighting quality、 and lighting power density values for various places of urban rail transit operation. This standard is applicable to the lighting of various places in urban rail transit operation. This standard is not applicable to the lighting of urban rail transit vehicles. 2 Normative References: The clauses in the following documents become clauses of this standard through reference in this standard. All dated references、 subsequent amendments (excluding corrected content) or revisions are not applicable to this standard. However、 all parties who have reached agreements based on this standard are encouraged to study whether new versions of these documents can be used. For undated reference documents、 the new version of * applies to this standard. GB/T 5700 Measurement Methods for Indoor Lighting GB 7000.1 Luminaires Part 1: General Requirements and Tests (GB 7000 1-2007.IEC 60598-1:2003、 IDT) GB 700.2 Luminaires - Part 2-22: Special requirements for emergency lighting fixtures (GB 7000 2-2008、 ide IEC 60598-2-22: 2002) GB 17625.1 Electromagnetic compatibility limits Harmonic current emission limits (equipment input current ≤ 16 A per phase) (GB 17625 1-2003、 IEC 61000-3-2:2001、 IDT) GB 17625.2 Electromagnetic Compatibility Limits - Limitations on Voltage Variations、 Voltage Fluctuations、 and Flashing of Equipment with a Rated Current of ≤ 16 A per Phase and Unconditionally Connected in Public Low Voltage Power Supply Systems (GB 17625 2-2007、 IEC 61000-3-3: 2005、 IDT) GB17896 Limits for Energy Efficiency and Energy Conservation Evaluation of Ballasts for Tubular Fluorescent Lamps GB 17945 Fire Emergency Luminaires (GB 17945-2000.neq IS0 6309:1987) GB 19574 Energy Efficiency Limits and Energy Efficiency Evaluation Values for Ballasts Used in High Pressure Sodium Lamps GB19043 Energy Efficiency Limits and Energy Efficiency Grades for Double ended Fluorescent Lamps Used in Caotong Lighting GB19044 Energy Efficiency Limits and Energy Efficiency Grades for Self ballasted Fluorescent Lamps Used in Caotong Lighting GB19415 Energy Efficiency Limits and Energy Efficiency Grades for Single ended Fluorescent Lamps GB 19573 Energy Efficiency Limits and Energy Efficiency Grades for High Pressure Sodium Lamps GB20053 Energy Efficiency Limits and Energy Efficiency Grades for Ballasts Used in Metal Halide Lamps GB 20054 Metal Halide Lamps The limited values and levels of energy efficiency for lamps GB/T 50033 Standard 3 for Daylighting Design in Buildings - Terms and Definitions - The following terms and definitions apply to this standard. 3.1 General lighting refers to the uniform lighting set up to illuminate the entire site surface. [JG]/T 119-2008、 3.1.1] 3.2 zoned general lighting. For a specific area、 such as a work site、 different illuminances are designed to illuminate the general lighting of the area. [JG]/T 119--3.1.3 in 2008]

Baijian is committed to providing convenient and efficient testing services for enterprises and individuals、 simplifying testing processes、 improving the efficiency of testing services、 making use of Internet plus testing e-commerce to provide customers with diversified choices、 fundamentally reducing testing costs、 improving time efficiency、 breaking industry limitations and bottlenecks、 and creating an innovative testing platform in the industry. If you need it、 please contact 1850176337

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific、 fair、 and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

inspection and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered、 meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing、 with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle、 low cost、 and attentive service

7. Possess authoritative qualifications such as CMA、 CNAS、 CAL、 etc

8. The testing report is authoritative and effective、 and is generally used in China

tags:

Random recommendation...

13262752056 扫描微信