Internal micrometer inspection

Material Analysis 百检检测 2024-03-01

1 Scope

This standard specifies the terms and definitions、 types and basic parameters、 requirements、 inspection methods、 markings、 and packaging of inner diameter indicator tables. This standard is applicable to inner diameter indicator meters with a graduation value or resolution of 0.01mm and 0.001mm、 and a measurement range of 6mm to 450mm

2 Normative References

The clauses in the following documents become the clauses of this standard through the reference surface of this standard.

. For dated reference documents、 all subsequent amendments (excluding corrected content) or revisions to this standard are not applicable. However、 parties who have reached agreements based on this standard are encouraged to investigate whether new versions of these documents can be used. For undated reference documents、 the new version of * applies to this standard

GB/T 17163-1997 Basic Terminology for Geometric Measurement Instruments

3 Terminology and Definitions.

The terms and definitions established in GB/T 17163-1997 and the following apply to this standard

3.1

Inner diameter indicator dial bore gauges

Using a mechanical transmission system、 the linear displacement of the movable measuring head is transformed into the angular displacement of the pointer on a circular dial、 and the dial is used to read

the internal dimension measuring instrument.

3.2

Adjacent error

The specified error * limit between adjacent inspection points on the inner diameter indicator.

3.3

Centering error

In measurement、 the error caused by the deviation of the connecting line between the movable and interchangeable measuring heads of the positioning bridge type inner diameter indicator and the contact point of the calibration ring gauge from the diameter of the calibration ring gauge.

3.4

Operating travel

The inner diameter indicator measuring head is used to measure the movement range.

3.5

Pre compression travel

The inner diameter indicator measures the pre compression amount before the working stroke of the head.

3.6

Length below grip of the lower part of the handle

The distance between the lower ends of the insulated hands and the centerline of the measuring head.

Baijian is committed to providing convenient and efficient testing services for enterprises and individuals、 simplifying testing processes、 improving the efficiency of testing services、 using Internet plus testing e-commerce to provide customers with diversified choices、 fundamentally reducing testing costs、 improving time efficiency、 breaking industry limitations and bottlenecks、 and creating an innovative testing platform in the industry. If you need it、 please contact 18501763637

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific、 fair、 and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

inspection and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered、 meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing、 with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle、 low cost、 and attentive service

7. Possess authoritative qualifications such as CMA、 CNAS、 CAL、 etc

8. The testing report is authoritative and effective、 and is generally used in China